Hi Stefan:

I have the same issue since I did an update on the unit. I have past logs with not showing this code.

Address 5F: Information Electr. (J794)       Labels:. 4E0-035-6xx-5F.clb
   Part No SW: 8R1 035 746 K    HW: 8R1 035 746 G
   Component: H-BNT-NA      H43 1040 
   Revision: --------    Serial number: 523E%0FB004993
   Coding: 1A0200060205A9EF7D02AF5E00000403140000000000000000
   Shop #: WSC 10008 005 104857
   VCID: 3FCEB594AEB9346EF2-806A

   Subsystem 1 - Part No: 8R0 060 884 CS
   Component: NAR 2015  1201

   Subsystem 2 - Part No SW: 8R0 919 604 A    HW: 8R0 919 604 A
   Component: DU7 High  H42 0104
   Serial number: A130E.0F3359764     

   Subsystem 3 - Part No SW: 8T0 919 611 L    HW: 8T0 919 611 C
   Component: E0380 Bedient  H02 0030
   Serial number: 00000002244495     

   Subsystem 4 - Part No: 8R0 060 961 G
   Component: CD-Database  6208

1 Fault Found:
04142 - LVDS Line for Display Module
            011 - Open Circuit - Intermittent
             Freeze Frame:
                    Fault Status: 00101011
                    Fault Priority: 6
                    Fault Frequency: 1
                    Reset counter: 68
                    Mileage: 198742 km
                    Time Indication: 0
                    Date: 2025.01.05
                    Time: 01:03:15

             Freeze Frame:
                    Voltage: 12.40 V