(7 replies, posted in English forum)

There is some news about shift light?

2

(7 replies, posted in English forum)

There is some news about shoft light?

3

(7 replies, posted in English forum)

stefan@fis-control wrote:

Hi, I now see that I have not finished the shift light feature.
I will try to add it with one of the next firmware updates.

Thank you very much.
I'll be anxiously awaiting the new update.

4

(7 replies, posted in English forum)

It is possible add a shift light indicator?

5

(30 replies, posted in English forum)

There is some setting to convert lambda volt in AFR?
In collection 1, I see only volt.

6

(30 replies, posted in English forum)

stefan@fis-control wrote:

Yes, it should be possible when you set SETTINGS -> HEADLINE -> RADIO.

Ok perfect.
Thank you very much for your help.

7

(30 replies, posted in English forum)

stefan@fis-control wrote:

Yes, you can change the label of a preset. I think I just left the label field for Preset 1 empty, so it will default to "PRESET 1". but you can enter a different name there.

Boost should be zero of Engine is off.

It is possible to see in the label of preset, the normal external temperature?

Like in this picture?

8

(30 replies, posted in English forum)

stefan@fis-control wrote:

I assume that you have selected "SAVE SETTINGS" after you uploaded the config file.
Do not do this, because this will overwrite the settings file with the currently active settings.
Just restart the ignition instead.

So:
Go to SETTINGS -> FLASH MEMORY -> LOAD SETTINGS -> BLUETOOTH
Then transfer the settings file.
When done, just restart the ignition.

Perfect now work.
It is possible to remove o change “preset 1” on top screen?
It is normal if the boost is not to zero?

9

(30 replies, posted in English forum)

stefan@fis-control wrote:

Hi, please try the attached settings file.

Same problem, i cant see a collection but one parameter every peset:

here a video:

https://www.icloud.com/attachment/?u=ht … =141929773

10

(30 replies, posted in English forum)

stefan@fis-control wrote:

No, the collections are not ok.
If you tell me, which measurements you want to have in your collections, I could create a config file for you.

I would want have:

Water temp        block 01 value 2
OIL temp           block 134 value 1
OIL level            block 09 value 1
Boost
Intake air temp  block 134 value 3
Cat temp           block 225 value 3

11

(30 replies, posted in English forum)

It is ok the file setting?

12

(30 replies, posted in English forum)

stefan@fis-control wrote:

Did you select SETTINGS -> FLASH MEMORY -> LOAD SETTINGS -> RS-232 in the FIS-Control?
You should see the letter C every second in the Terminal program on your laptop then.

Now work.

13

(30 replies, posted in English forum)

stefan@fis-control wrote:

Did you set the baudrate correctly? For USB cable it is necessary to set it to 115200 bit/s.

yes have set 115200

14

(30 replies, posted in English forum)

stefan@fis-control wrote:

To configure the "Labels for measurment values", you have to use the configurator:
https://fis-control.de/config_en.html

About your black screen problem. Would it be possible that you send me your settings file?
Here is explained how to receive the settings from the FIS-Control with a Windows laptop:
https://www.youtube.com/watch?v=2eTrsIlG-v0

I tried to connect with a usb-com adapter, but I can't connect to the fis control.
I don’t have Bluetooth on may laptop.

15

(30 replies, posted in English forum)

stefan@fis-control wrote:

Hi,

no problem, I can give an example.
Let's say you want to show a collection with these six measurements from the engine control unit:
Line 1: measuremet block 10, value 1
Line 2: measuremet block 20, value 2
Line 3: measuremet block 30, value 3
Line 4: measuremet block 40, value 4
Line 5: measuremet block 50, value 1
Line 6: measuremet block 60, value 2


You have to go to SETTINGS -> COLLECTION and select COLLECTION 1.
Now select LINE 1, then go to GROUP and select 10, then go to VALUE and select 1.
Now select LINE 2, then go to GROUP and select 20, then go to VALUE and select 2.
Now select LINE 3, then go to GROUP and select 30, then go to VALUE and select 3.
Now select LINE 4, then go to GROUP and select 40, then go to VALUE and select 4.
Now select LINE 5, then go to GROUP and select 50, then go to VALUE and select 1.
Now select LINE 6, then go to GROUP and select 60, then go to VALUE and select 2.

This will configure the collection. Now you have to configure where the collection shall be shown.
Let's say you want it in PRESET 1.

Go to SETTINGS -> PRESETS -> PRESET 1 and set the following:
CONTROL UNIT: 01 EINGINE
GROUP: 10 (this should be the first group that is used in your collection)
VALUE: 1 (this selects that you want to show the first collection)
VIEW: COLLECTION

That's it.

I have made like this, but continue to see black screen.
If select single value I see only the number but not what is it (like oli temp o speed)

16

(30 replies, posted in English forum)

Is not possible in the collection 1 (for example) have other value from other control unit?
Engine, dsg, haldex 4x4…

17

(30 replies, posted in English forum)

stefan@fis-control wrote:

Hi,

no problem, I can give an example.
Let's say you want to show a collection with these six measurements from the engine control unit:
Line 1: measuremet block 10, value 1
Line 2: measuremet block 20, value 2
Line 3: measuremet block 30, value 3
Line 4: measuremet block 40, value 4
Line 5: measuremet block 50, value 1
Line 6: measuremet block 60, value 2


You have to go to SETTINGS -> COLLECTION and select COLLECTION 1.
Now select LINE 1, then go to GROUP and select 10, then go to VALUE and select 1.
Now select LINE 2, then go to GROUP and select 20, then go to VALUE and select 2.
Now select LINE 3, then go to GROUP and select 30, then go to VALUE and select 3.
Now select LINE 4, then go to GROUP and select 40, then go to VALUE and select 4.
Now select LINE 5, then go to GROUP and select 50, then go to VALUE and select 1.
Now select LINE 6, then go to GROUP and select 60, then go to VALUE and select 2.

This will configure the collection. Now you have to configure where the collection shall be shown.
Let's say you want it in PRESET 1.

Go to SETTINGS -> PRESETS -> PRESET 1 and set the following:
CONTROL UNIT: 01 EINGINE
GROUP: 10 (this should be the first group that is used in your collection)
VALUE: 1 (this selects that you want to show the first collection)
VIEW: COLLECTION

That's it.

Thank you very much

18

(30 replies, posted in English forum)

I have seen the instruction, but without example I can’t do it right.
Also on YouTube can’t found a video (in English) with example to made a first collection.

19

(30 replies, posted in English forum)

Hello, Someone can halp me Step by step, how to set the collection on the main screen?
I tried, but I always have the black screen without data.